Multi range on delay interval equal repeat unequal repeat
On-delay: At power-up (or reset), the relay is de-energized until the preset time has lapsed, then the relay energizes until the power is removed, or the device is reset.
Interval: At power-up (or reset), the relay is energized until the pre-set time has lapsed, then the relay de-energizes until the power is removed, or the device is reset.
Repeat: The relay continuously switches between the individually adjustable pre-set "on" and "off" times.
Additional features include:
Adjustable parameters
time range 1 sec - 99 min
1 min - 99 hours
pulse controlled on / off
if pulse controlled open / close contact
on time see time range
off time see time range
if repeat timer, start cycle on time / off time
save status on power fail on: cont cycle
off: reset cycle at power up
incorporates a crystal oscillator to maintain timing accurate timing